Jundishapur Scientific Medical Journal

Jundishapur Scientific Medical Journal

The Effect of Brightness Filter Alterations for Detecting Internal Root Resorption in Single Root Teeth in Cone Beam Computed Tomography: An In-Vitro Study

Document Type : Original Article

Authors
1 Assistant Professor, Department of Endodentics, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
2 Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
3 Post Gratituded, Department of Oral and Maxillofacial Radiology, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
4 Dentist, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
5 Assistant Professor, Department of Oral and Maxillofacial Surgery, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran .
6 Assistant Professor, Department of Oral and Maxillofacial Pathology, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
10.32592/jsmj.23.6.535
Abstract
Background and Objectives Diagnosis of internal root resorption in anterior teeth, which are important in terms of beauty and mental health, is of great importance. There are several processing algorithms to facilitate the interpretation of the images used to diagnose and treat internal analysis, one of which is brightness. The aim of this study was to investigate the effect of brightness changes on the diagnosis of endodontic resorption in single-rooted teeth in tomography.
Subjects and Methods Forty-five single root teeth with were splinted mesiodistally in this in vitro case-control study. Artificial internal resorption lesions were created in cervical, middle or apical areas. CBCT images were taken before and after cavity preparation. CBCT images was evaluated by Two radiologists in low, intermediate and high brightness value. The data were analyzed using Kappa and Mac-Nemar tests on SPSS software. Overall accuracy was evaluated with sub curve analysis of ROC.
Results Specificity, sensitivity and overall accuracy were calculated using Kappa statistical analysis test of all brightness images (low-medium-high) showed only for second observer between low brightness images and reality meaningful difference exist. Also, sensitivity, specificity and overall accuracy were high for both observers and also slightly higher in high brightness images.
Conclusion from present study we can conclude that in using of brightness filter in CBCT images, high brightness has more conformity with reality and can be useful.
Keywords
Subjects

  • Tsai KZ, Tsai SC, Lin KH, Chang YC, Lin YP, Lin GM. Associations of decayed teeth and localized periodontitis with mental stress in young adults: CHIEF oral health study. Scientific Reports. 2022 Nov 9;12(1):19139. [10.1038/s41598-022-23958-4 ] [PMID]
  • Patel S, Saberi N, Pimental T, Teng PH. Present status and future directions: Root resorption. International Endodontic Journal. 2022 Oct;55:892-921.[ 10.1111/iej.13715 ][PMID]
  • Baranova J, Büchner D, Götz W, Schulze M, Tobiasch E. Tooth formation: are the hardest tissues of human body hard to regenerate?. International journal of molecular sciences.2020 Jan;21(11):4031.[ 10.3390/ijms21114031 ] [PMID]
  • Agrawal V, Shah A, Kapoor S. Non-perforating internal resorption-diagnosis and endodontic management in maxillary lateral incisor. Clinical Dentistry (0974-3979). 2020 Aug 1;14(8).
  • Cantu AG, Gehrung S, Krois J, Chaurasia A, Rossi JG, Gaudin R, Elhennawy K, Schwendicke F. Detecting caries lesions of different radiographic extension on bitewings using deep learning. Journal of dentistry. 2020 Sep 1;100:103425.[ 10.1016/j.jdent.2020.103425 ][PMID]
  • Cotti E, Schirru E. Present status and future directions: Imaging techniques for the detection of periapical lesions. International Endodontic Journal. 2022 Oct;55:1085-99.[ 10.1111/iej.13828 ] [PMID]Ylli D, Sidhu S, Parikh T, Burman KD. Endocrine changes in obesity. Endotext [Internet]. 2022. [ 1111/iej.13828 ] [PMID]
  • Singh N, Yadav R, Duhan J, Tewari S, Gupta A, Sangwan P, Mittal S. Comparative analysis of the accuracy of periapical radiography and cone‐beam computed tomography for diagnosing complex endodontic pathoses using a gold standard reference–A prospective clinical study. International endodontic journal. 2021 Sep 1;54(9).[ 10.1111/iej.13535 ][PMID]
  • Rodríguez-López S, Escobedo Martínez MF, Junquera L, García-Pola M. Two-dimensional analysis of digital images through vector graphic editors in dentistry: new calibration and analysis protocol based on a scoping review. International Journal of Environmental Research and Public Health. 2021 Apr 23;18(9):4497.[ 10.3390/ijerph18094497 ][PMID]
  • Cotti E, Schirru E. Present status and future directions: Imaging techniques for the detection of periapical lesions. International Endodontic Journal. 2022 Oct;55:1085-99.[ 10.1111/iej.13828 ][PMID]
  • Bakry AM, Mahmoud EF, Sayed MM. Diagnostic Accuracy of Digital Periapical Radiography and Cone-beam Computed Tomography in Detection of Simulated External Root Resorption. Al-Azhar Assiut Dental Journal. 2022 Oct 1;5(2):209-14.Lin D, Liu T, Chen L, Chen Z. Body mass index in relation to prostate-specific antigen-related parameters. BMC Urol. 2021;
    21(1):130. [DOI: 10.1186/s12894-020-00746-8] [PMID] [PMCID]
  • Hou Y, Feng G, Lin W, Wang R, Yuan H. Observation of retromolar canals on cone beam computed tomography. Oral Radiology. 2020 Oct;36:365-70.[ 10.1007/s11282-019-00414-0 ][PMID]
  • Hussain S, Mubeen I, Ullah N, Shah SS, Khan BA, Zahoor M, Ullah R, Khan FA, Sultan MA. Modern diagnostic imaging technique applications and risk factors in the medical field: a review. BioMed research international. 2022;2022(1):5164970.[10.1155/2022/5164970 ][PMID]
  • Umbaugh SE. Digital image processing and analysis: digital image enhancement, restoration and compression. Crc Press; 2022 Dec 30.
  • Qassim HM, Basheer NM, Farhan MN. Brightness preserving enhancement for dental digital X-ray images based on entropy and histogram analysis. Journal of Applied Science and Engineering. 2019 Mar;22(1):187-94.
  • MehrAli Zadeh S, Talayi poor A, Mehrvarzfar P, Edalat M, SHarifi SHoushtari S. Comparison between digital intraoral radiography (PSP) and Cone Beam CT images in detection internal root resorption (in-vitro study). J Res Dent Sci. 2016;13(2) :102-8.
  • White SC, Pharoah MJ. Oral radiology: principles and interpretation. St. Louis, MO: Mosby. Elsevier. 2009;6:70-3.
  • Kumari M. New Caries Diagnostic Methods-A Review. Clinical Dentistry (0974-3979). 2022 Jul 1;16(7).
  • Zehnder M, Belibasakis GN. A critical analysis of research methods to study clinical molecular biomarkers in Endodontic research. International EndodonticJournal.2022Mar;55:37-45. [10.1111/iej.13647 ][PMID]
  • Singh N, Yadav R, Duhan J, Tewari S, Gupta A, Sangwan P, Mittal S. Comparative analysis of the accuracy of periapical radiography and cone‐beam computed tomography for diagnosing complex endodontic pathoses using a gold standard reference–A prospective clinical study. International endodontic journal. 2021 Sep 1;54(9). [10.1111/iej.13535 ][PMID]
  • Heboyan A, Avetisyan A, Karobari MI, Marya A, Khurshid Z, Rokaya D, Zafar MS, Fernandes GV. Tooth root resorption: A review. Science Progress. 2022 Jul;105(3):00368504221109217. [10.1177/00368504221109217 ][PMID]
  • Pereira SA, Corte-Real A, Melo A, Magalhães L, Lavado N, Santos JM. Diagnostic Accuracy of Cone Beam Computed Tomography and Periapical Radiography for Detecting Apical Root Resorption in Retention Phase of Orthodontic Patients: A Cross-Sectional Study. Journal of Clinical Medicine. 2024 Feb 22;13(5):1248. [10.3390/jcm13051248 ][PMID]
  • Archana R, Jeevaraj PE. Deep learning models for digital image processing: a review. Artificial Intelligence Review. 2024 Jan;57(1):11.
  • Wanderley VA, Leite AF, de Faria Vasconcelos K, Pauwels R, Müller-García F, Becker K, Oliveira ML, Jacobs R. Impact of metal artefacts on subjective perception of image quality of 13 CBCT devices. Clinical oral investigations. 2022 Jun;26(6):4457-66. [10.1007/s00784-022-04409-w ][PMID]
  • Wang Y, Xie W, Liu H. Low-light image enhancement based on deep learning: a survey. Optical Engineering. 2022 Apr 1;61(4):040901-.
  • Farhadi N, Shokraneh A, Mehdizadeh M. Effect of contrast inversion enhancement on the accuracy of endodontic file length determination in digital radiography. Journal of Clinical and Diagnostic Research: JCDR. 2015 May;9(5):ZC102. [10.7860/JCDR/2015/11767.5988 ][PMID]
  • de Azevedo Vaz SL, Vasconcelos TV, Neves FS, de Freitas DQ, Haiter-Neto F. Influence of cone-beam computed tomography enhancement filters on diagnosis of simulated external root resorption. Journal of endodontics. 2012 Mar 1;38(3):305-8. [10.1016/j.joen.2011.10.012 ][PMID]
  • Habibi Kia A, Dabaghi A, Javaheri M, Sabaghian M. Evaluation of Contrast Alternation Efficacy in Diagnosis of Vertical Root Fracture in Conventional Digital Radiography (An Ex-vivo Study). Jundishapur Scientific Medical Journal. 2022 Feb 20;20:680-9.
  • Kia AH, Dabaghi A, Javaheri MA, Sabaghian M. Research Paper Evaluation of Contrast Alternation Efficacy in Diagnosis of Vertical Root Fracture in Conventional Digital Radiography (An Ex-vivo Study).2016 Apr 7;11:230-4.
Volume 23, Issue 6 - Serial Number 153
January and February 2025
Pages 535-548

  • Receive Date 30 October 2021
  • Revise Date 06 July 2024
  • Accept Date 04 August 2024