<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه علوم پزشکی جندی شاپور اهواز</PublisherName>
				<JournalTitle>مجله علمی پزشکی جندی شاپور</JournalTitle>
				<Issn>2252-052X</Issn>
				<Volume>15</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2016</Year>
					<Month>09</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Calculation of Dosimetric Parameters for 252Cf-AT Brachytherapy Source using Monte Carlo Simulation</ArticleTitle>
<VernacularTitle>محاسبۀ پارامترهای دزیمتری چشمۀ براکی تراپی 252Cf-AT با استفاده از شبیه‌سازی مونت کارلو</VernacularTitle>
			<FirstPage>383</FirstPage>
			<LastPage>390</LastPage>
			<ELocationID EIdType="pii">46971</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>راحله</FirstName>
					<LastName>طبری جویباری</LastName>
<Affiliation>مربی گروه رادیولوژی.گروه رادیولوژی، دانشکدۀ علوم پزشکی بهبهان، بهبهان، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>فواد</FirstName>
					<LastName>گلی احمدآباد</LastName>
<Affiliation>مربی گروه بیوشیمی و فیزیک پزشکی.دانشکدۀ پزشکی، دانشگاه علوم پزشکی جیرفت، جیرفت، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>هادی</FirstName>
					<LastName>رضایی</LastName>
<Affiliation>کارشناس‌ارشد فیزیک پزشکی گروه رادیولوژی.گروه رادیولوژی، دانشکدۀ پیراپزشکی، دانشگاه علوم پزشکی شیراز، شیراز، ایران.
4-فیزیک پزشکی، فیزیست بیمارستان پارسیان</Affiliation>

</Author>
<Author>
					<FirstName>فریبا</FirstName>
					<LastName>عینی</LastName>
<Affiliation>کارشناس‌ارشد فیزیک پزشکی.فیزیک پزشکی، فیزیست بیمارستان پارسیان شهرکرد، شهرکرد، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>میثم</FirstName>
					<LastName>فروزی</LastName>
<Affiliation>کارشناس‌ارشد فیزیک.کارشناس ارشد فیزیک، دانشکدۀ علوم، دانشگاه شیراز، شیراز، ایران.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>01</Month>
					<Day>21</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background and Objective: &lt;/strong&gt;Nowadays, the use of simulation for accurate determination of dosimetric parameters is inevitable. In this study dosimetric parameters &lt;sup&gt;252&lt;/sup&gt;CF-AT as a neutron brachytherapy sources using Monte Carlo simulation was calculated for treatment planning of some uterus and brain tumors.
&lt;strong&gt;Materials and Methods: &lt;/strong&gt;Thephysical and geometrical characteristic of &lt;sup&gt;252&lt;/sup&gt;Cf-AT source were estimated by MCNPX (2.6.0) code and the air kerma strength of the source placed inside the vacuum sphere was calculated. Recommended dosimetric parameters by AAPM, TG-43 protocol were determined for source positioned in a homogeneity water phantom.
&lt;strong&gt;Results: &lt;/strong&gt;The air kerma strength of 252 Cf source was estimated 0.33 (cGycm&lt;sup&gt;2&lt;/sup&gt;/μg.h). The neutron dose rate constant using *F8 and F6 tallies was calculated 5.7524 (cGy/U.h), 5.650816 (cGy/U.h) respectively. The radial dose function with 5 degree equation was obtained. Numerical amounts of the anisotropy dose functions and the related equations were also calculated.
&lt;strong&gt;Conclusion:&lt;/strong&gt; The calculated dosimetric parameters of the model &lt;sup&gt;252&lt;/sup&gt;Cf-AT source by Monte Carlo code are in good agreement with experimental results and previous calculations. The calculated values can be used by treatment planning systems for the &lt;sup&gt;252&lt;/sup&gt;Cf-AT source brachytherapy.
&lt;strong&gt; &lt;/strong&gt;
&lt;strong&gt; &lt;/strong&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;strong&gt;زمینه و هدف: &lt;/strong&gt;امروزه استفاده از شبیه­سازی برای تعیین دقیق پارامترهای دزیمتری اجتناب­ناپذیر است. در این مطالعه پارامترهای دزیمتری &lt;sup&gt;252&lt;/sup&gt;Cf-AT به‌عنوان یک چشمه نوترونی براکی تراپی با استفاده از شبیه­سازی مونت­کارلو محاسبه می­شود که در درمان برخی از سرطان­های رحم و تومورهای مغزی کاربرد دارد.
&lt;strong&gt;روش بررسی: &lt;/strong&gt;ویژگی­های فیزیکی و هندسی چشمه کالیفورنیوم-252 مدل AT با استفاده از کد شبیه­سازی MCNPX (2.6.0) تخمین زده شده و قدرت کرمای هوا در داخل یک کره خلأ محاسبه شد. پارامترهای دزیمتری برای چشمه قرار گرفته در یک فانتوم یکنواخت آب و بر اساس پروتکل TG-43 پیشنهاد شده توسط AAPM تعیین شد.
&lt;strong&gt;یافته­ها:&lt;/strong&gt; قدرت کرمای نوترون هوای چشمه  Cf&lt;sup&gt;252&lt;/sup&gt; در واحد اکتیویته برابر با (cGy cm&lt;sup&gt;2&lt;/sup&gt;/μgh) 33/0 تخمین زده شد. ثابت آهنگ دز نوترون Λ&lt;sub&gt;N&lt;/sub&gt;، برای *F8 و F6 به ترتیب برابر با  cGy/Uh7524/5 و cG/Uh 650816/5 تخمین زده شد. تابع شعاعی دز با یک معادلۀ درجۀ پنجم به دست آمد. مقادیر عددی و معادلات مربوطه به توابع آنیزوتروپی دز F(r,θ)، نیز تخمین زده شد.
&lt;strong&gt;نتیجه­گیری:&lt;/strong&gt; پارامترهای دزیمتری برای چشمۀ Cf&lt;sup&gt;252&lt;/sup&gt; مدل AT که با کد مونت کارلو محاسبه شده است، همخوانی خوبی با نتایج تجربی و محاسبه شدۀ قبلی دارد. مقادیر محاسبه شده می­تواند در نرم­افزارهای طراحی درمان براکی تراپی با چشمۀ &lt;sup&gt;252&lt;/sup&gt;Cf-AT مورد استفاده قرار گیرد.
&lt;strong&gt; &lt;/strong&gt;
&lt;strong&gt; &lt;/strong&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">براکی تراپی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">دزیمتری نوترون</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">چشمۀ 252Cf-AT</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شبیه­سازی مونت کارلو</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jsmj.ajums.ac.ir/article_46971_f7baa5d5ed7d88c6b4a99873955915a0.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
